Skip to content
Mechanical Inspection

LNG Preconditioning Plant — Auxiliary Gearbox Inspection

Auxiliary gearbox inspection for ADNOC LNG preconditioning plant

Project Overview

DualTech Conseil carried out the inspection of an auxiliary gearbox (GT) — S/N 17877, Type DF51BB — for the ADNOC GAS LNG Preconditioning Plant (LPP) project. The gearbox is a critical component in the gas turbine auxiliary drive system.

Scope of Inspection

  • Visual and dimensional inspection of the gearbox housing
  • Tooth contact pattern verification on gear pairs
  • Backlash measurement on all gear meshes
  • Non-destructive testing (NDT) on welds and critical sections
  • Dimensional verification of shaft alignment
  • Documentation review (material certificates, ITP)

Standards Applied

API 613 — Special-purpose gear units for petroleum, chemical and gas industry services.

Deliverables

Inspection report with dimensional data sheets, tooth contact pattern photos, NDT results, and final release recommendation.